马兴 郭贵勇
摘 要:本文介绍了砂当量试验仪的工作原理和用途,建立了砂当量试验仪校准结果的测量模型,分析了各不确定度分量主要来源,结合测量实例具体数据,对其合成不确定度进行分析评定,对各不确定度分量进行计算并得出合成不确定度和扩展不确定度,最终可得出该项目的校准测量能力,为公路、市政等部门提供技术支撑。
关键词:砂当量试验仪 校准方法 测量 性能影响 不确定度评定
中图分类号:TH871 文献标识码:A 文章编号:1674-098X(2020)01(a)-0052-02
Abstract: This paper introduces the working principle and application of sand equivalent tester, establishes the measurement model of the calibration results of the interface tension meter, analyzes the main sources of each uncertainty component, analyzes and evaluates the synthetic uncertainty combined with the concrete data of the measurement example, calculates each uncertainty component, obtains the synthetic uncertainty and extended uncertainty. Finally, the calibration and measurement ability of the project can be obtained. Overall, this paper can provide strong technical support for highways, municipalities and other department.
Key Words: Sand Equivalent Tester; Calibration Method; Measurement; Performance Impact; evaluation of Uncertainty
砂當量测定仪是一种测定仪,适用于沥青混合料及水泥混凝土,用天然砂、人工砂、石屑,其集料最大粒径不超过4.75mm,测定细集料中所含的粘性土或杂质的含量,以评定集料的洁净程度。
1 砂当量测定仪的校准
砂当量测定仪的校准是将反光纸贴在振荡部分的末端,用高精度标准智能测速频率仪对准反光纸部位,运行砂当量试验仪,测出砂当量试验仪振动频率,测量3次,取其平均值;用记号笔做好砂当量试验仪的振荡器做直线振荡时的始末位置,用游标卡尺量出两记号位置的间距即为砂当量试验仪振荡器的振幅,测量三次,取其平均值。
4 结语
保证砂当量测定仪的准确性,通过校准等方法实现量值的溯源性,在公路、市政等部门细集料的质量控制中起到重要作用;本文介绍我院对砂当量测定仪进行校准方法和不确定度评定方法。
参考文献
[1] 中华人民共和国交通运输部.JJG(交通)137-2017,《砂当量测定仪》[S].北京:人民交通出版社,2017.
[2] 郑义.砂当量及其测定方法[J].国外公路,1986(4):55-57.
[3] 朱立无,朱岩.砂当量试验仪校准结果不确定度评定[J].计量与测试技术,2019(5):107-110.